Specification |
Test Description |
IEC-61000-3-2 |
HARMONIC CURRENTS EMISSION |
IEC-61000-3-3 |
VOLTAGE FLUCTUATIONS & FLICKER |
IEC-61000-4-13 |
IMMUNITY TO HARMONICS |
IEC-61000-4-2 |
ELECTROSTATIC DISCHARGE IMMUNITY |
IEC-61000-4-4 |
EFT BURST IMMUNITY TEST |
IEC-61000-4-5 |
SURGE IMMUNITY TEST |
IEC-61000-4-6 |
RF CONDUCTED IMMUNITY |
IEC-61000-4-8 |
POWER FREQUENCY MAGNETIC FIELDIMMUNITY TEST |
IEC-61000-4-9 |
PULSE MAGNETIC FIELD IMMUNITY TEST |
IEC-61000-4-11 |
VOLTAGE DIPS, VOLTAGE INTERRUPTIONS, AND VOLTAGE
VARIATIONSIMMUNITY TESTS |
IEC-601-1-2 (MEDICAL) refers to these IEC specifications:
-
IEC-61000-4-2
-
IEC-61000-4-3
-
IEC-61000-4-4
-
IEC-61000-4-5
-
IEC-61000-4-6
-
IEC-61000-4-8
-
IEC-61000-4-11
EN50082-1
Generic Immunity Standard, Residential, Commercial, and Light Industry
Test
ELECTROSTATIC DISCHARGE (ESD)
EN61000-4-2:1995
+/-8KV, Air discharge, +/-4KV Contact discharge
RADIATED RF ELECTROMAGNETIC FIELDS
ENV50140:1996
3
V/M 80% AM @ 3 Meters
80Mhz
- 1,000Mhz
RADIATED 900MHZ PULSE
ENV50204:1995
900Mhz,
3 V/M, 50% duty cycle@200Hz rate
ELECTRICAL FAST TRANSIENTS (EFT)
EN61000-4-4:1995
+/-
1KV Supply &Control
+/- 500
V, Data &Signal Lines
SURGE IMMUNITY TEST (Lightning Strikes to Power Lines )
EN61000-4-5:1995
+/-
1KV Line to line
+/-
2KV Line to earth
CONTINUOUS CONDUCTED INTERFERENCE
ENV50141
3
Volts RMS, 150Khz - 80Mhz, 80% AM
POWER FREQUENCY MAGNETIC FIELDS
EN61000-4-8:1993
3
Amps/m, 50Hz
VOLTAGE DIPS AND SHORT INTERRUPTIONS
EN61000-4-11:1995
100%
dip for 10mSecs
60%
dip for 100mSecs
30%
dip for 1 second
100%
interruption for 5 seconds
EN50082-2
Generic Immunity Standard, Industrial Environment Test
ELECTROSTATIC DISCHARGE (ESD)
EN61000-4-2:1995
+/-8KV,
Air discharge,
+/-4KV
Contact discharge
RADIATED RF ELECTROMAGNETIC FIELDS
ENV50140:1996
10
V/M 80% AM
@
3 Meters
80Mhz
- 1,000Mhz
RADIATED 900Mhz PULSE
ENV50204:1995
10V/M,
900Mhz
Pulsed
@ 50% Duty Cycle
200Hz
Rate
ELECTRICAL FAST TRANSIENT BURSTS
EN61000-4-4:1995
+/-1KV Supply And Control
Lines
+/-
500V Data And Signal
Lines
SURGE
EN61000-4-5:1995
+/-1KV
Line to Line
+/-
2KV Line to Earth
CONTINUOUS CONDUCTED INTERFERENCE
ENV50141
10V/M With 80% AM, 150Khz
- 80Mhz
POWER FREQUENCY MAGNETIC FIELDS
EN61000-4-8:1993
3A/m,
50Hz
VOLTAGE DIPS AND SHORT INTERRUPTIONS
EN61000-4-11:1995
30% Dip @ 10mSecs
60% Dip @ 100mSecs
>95% Interrupt @ 5 Secs
|